MIL-DTL-17124F
3.10 Cold conditioning (applicable to Type I and II). The detonating cord shall
show no change in physical or performance characteristics - such as form, color, diameter,
breaking strength, and velocity of detonation - after being conditioned at -65 ± 5°F for a
minimum of 72 hours.
3.11 Flexibility (applicable to Type I, II, and III). The detonating cord shall not
crack after being conditioned at -65 ± 5°F for a minimum of 72 hours and then wrapped
five turns around a mandrel. For detonating cords with a measured outer diameter of 0.25
inches or less, a 0.25 ± 0.01 inch diameter mandrel shall be used. For detonating cords
with a measured outer diameter greater than 0.25 inches, a 0.75 ± 0.01 inch diameter
mandrel shall be used.
3.12 Ammunition lot numbering. Ammunition lot numbers shall be assigned in
accordance with MIL-STD-1168.
3.13 Workmanship. All parts, sub-assemblies, and assemblies shall be clean and free
of burrs, cracks, blisters, chips, dirt, grease, oil (except where specifically required), rust, salt
deposits, corrosion, and other foreign matter. All required markings shall be neat, legible, only
where specified, and sharply defined.
4. VERIFICATION
TABLE I. Requirement/verification cross reference matrix.
Method of verification
Classes of verification
1 - Analysis
2 - Demonstration
A First article
3 - Examination
4 - Test
B Conformance
Section
Description
Verification Verification
Section 4
Methods
Class
3
1234
A
B
3.1.1
First article
XX
X
4.2
3.1.2
Conformance inspection
XX
X 4.3
3.2
Materials, components and assemblies
XX
X
X 4.3.4.1, 4.3.4.2,
4.4 - 4.11
3.2.1
Detonation of velocity (applicable Type I and II)
X
X
X 4.12
3.3
Propagation of detonation (applicable to Type I)
X
X
X 4.13
3.4
Cut-off (applicable to Type Ip)
X
X
X 4.14
3.5
Detonation of TNT (applicable to Type Ib, Ic, Ij)
X
X
X 4.15
3.6
Flame sensitivity (applicable to Type I and II)
X
X
X 4.16
3.7
Impact sensitivity (applicable to Type I and II)
X
X
X 4.17
3.8
Waterproofness (applicable to Type I and II)
X
X
X 4.18
3.9
Solar radiation (applicable to Type I and II)
X
X
X 4.19
3.10
Cold conditioning (applicable to Type I and II)
X
X
X 4.20
3.11
Flexibility (applicable to Type I, II and III)
X
X
X 4.21
3.12
Ammunition lot numbering
X
X
X 4.3.4.1
3.13
Workmanship
X
X
X 4.3.4.1
4
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.