MIL-DTL-46550D(AR)
without evidence of weld failure, either cracking, separating, or pulling apart. The test shall be
performed as specified in 4.3.3.1.
3.5 Waterproofness of closing cap assembly and metal parts assembly. The closing cap
assembly and the metal parts assembly shall not exhibit leakage when pressurized 2 to 3 psi
internally with air for 10 seconds when tested as specified in 4.3.3.2.
3.6 Fit of closing cap assembly and metal parts assembly. The closing cap assembly
shall require a force fit to be joined to the metal parts assembly as specified in 4.3.3.3.
3.7 Workmanship. All parts and assemblies shall be accomplished in a thorough
workmanlike manner. They shall be clean and free of cracks, dents, burrs, sharp edges, surface
defects, dirt, grease, weld splatter, rust, corrosion, and other defects and foreign matter. The
cleaning method used shall not be injurious to any part or assembly nor shall the parts be
contaminated by the cleaning agent. Surface coatings shall be continuous. All required markings
shall be neat and sharply defined.
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business