MIL-DTL-45468F(AR)
4.3.1 Inspection lot formation. Lot formation shall be in accordance with the lot
requirement of MIL-STD-1916. Lot numbering, as required, shall be in accordance with MIL-
STD-1168. Each inspection lot of loaded charge assemblies shall contain:
a. Parts from not more than one lot interfix number from one manufacturer.
b. Ignition charge from not more than one lot from one manufacturer.
c. Lead azide from not more than one lot from one manufacturer.
d. RDX from not more than one lot from one manufacturer.
4.3.2 Examination. For the conformance inspection paragraphs 4.3.2.2 to 4.3.2.9, the
definitions of critical, major, and minor defects are provided in paragraph "Definitions" of MIL-
STD-1916. Inspection sampling requirements for critical, major, and minor characteristics aree
defined in MIL-STD-1916. Unless specified otherwise, Inspection Level VII in addition to
100% inspection shall be used for all characteristics defined as Critical, Inspection Level IV shall
be used for characteristics defined as Major, and Inspection Level II for all Minor characteristics.
Three characteristics are defined as Critical in 4.3.2.5.
4.3.2.1 Allowance for failure mode. A lot shall be accepted with one function failure as
long as there is evidence of bridgewire failure. Bridgewire failure shall be determined by a
continuity check prior to functioning and does not replace the inspection in 3.6.
Plug assembly (rubber).
4.3.2.2
DRAWING NUMBER
8830971
NEXT HIGHER ASSEMBLY
8830972
CONFORMANCE
REQUIREMENT
PARAGRAPH REFERENCE/
EXAMINATION OR TEST
CRITERIA
PARAGRAPH
INSPECTION METHOD
CATEGORY
Critical
None defined
Major
101
Pull test of lead wires
IV
3.5
4.3.4
Length of bare wire not covered by
IV
3.2
Gage
102
rubber plug
Length from bare end of lead wire
IV
3.2
Gage
103
to insulation, max.
104
Length of plug, min.
IV
3.2
Gage
105
Bridge wire improperly soldered
IV
3.2
Visual
106
Tension on bridge wire
IV
3.2
Visual
Resistance of bridge wire and lead
100%
3.6
SME
107
wires
Minor
201
Diameter of plug, min.
II
3.2
Gage
202
Evidence of poor workmanship
II
3.11
Visual
7